Tone Detection Parameters
The signal tone detection parameters are described in the table below.
Tone Detection Parameters
| Parameter | Description | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| dtmf-detector-enable [DTMFDetectorEnable] | Enables the detection of DTMF signaling. 
 
 | ||||||||||||||||||||||||||||||
| mfr1-detector-enable [MFR1DetectorEnable] | Enables the detection of MF-R1 signaling. 
 
 | ||||||||||||||||||||||||||||||
| mf-transport-type [MFTransportType] | Defines the method for sending MF digits over the network to the remote side. 
 
 
 | ||||||||||||||||||||||||||||||
| [R1DetectionStandard] | Determines the MF-R1 protocol used for detection. 
 
 Note: For the parameter to take effect, a device restart is required. | ||||||||||||||||||||||||||||||
| user-defined-tones-detector-enable [UserDefinedToneDetectorEnable] | Enables the detection of User Defined Tones signaling, applicable for Special Information Tone (SIT) detection. 
 
 | ||||||||||||||||||||||||||||||
| sit-detector-enable [SITDetectorEnable] | Enables SIT detection according to the ITU-T recommendation E.180/Q.35. 
 
 To disconnect IP-to-ISDN calls when a SIT tone is detected, configure the following parameters: 
 
 
 Another parameter for handling the SIT tone is [SITQ850Cause], which defines the Q.850 cause value specified in the SIP Reason header that is included in a 4xx response when a SIT tone is detected on an IP-to-Tel call. To disconnect IP-to-Tel calls when a SIT tone is detected, configure the following parameters: 
 
 
 Note: 
 
 | ||||||||||||||||||||||||||||||
| udt-detector-frequency-deviation [UDTDetectorFrequencyDeviation] | Defines the deviation (in Hz) allowed for the detection of each signal frequency. The valid range is 1 to 50. The default is 50. Note: For the parameter to take effect, a device restart is required. | ||||||||||||||||||||||||||||||
| cpt-detector-frequency-deviation [CPTDetectorFrequencyDeviation] | Defines the deviation (in Hz) allowed for the detection of each CPT signal frequency. The valid range is 1 to 30. The default is 10. Note: For the parameter to take effect, a device restart is required. |